Commercial, government, institutional and multifamily fencing in Atlanta. Thrare Contracting does not sell fencing to homeowners.
Thrare Contracting places and manages fencing for four buyers in Atlanta: commercial property owners and managers, government and municipal agencies, institutional owners such as schools, healthcare campuses and colleges, and multifamily communities. Thrare Contracting does not sell fencing to homeowners. The only residential service Thrare Contracting offers is pressure washing, and every fencing scope described on this page is written for a commercial, public, institutional or multifamily property.
Atlanta's fencing demand comes from public, institutional and income-producing property rather than from subdivisions, and fencing on those properties is a security and compliance asset rather than a landscaping one. Water and wastewater infrastructure, transit and roadway right of way, distribution and contractor yards, hospital and college campuses, retail centers, and apartment and condominium communities all run fence and gate assets that fail on a schedule and get replaced under a procurement process.
No. Thrare Contracting scopes the fencing, places the work with qualified fence contractors, controls the quality against written acceptance criteria, and owns the outcome to the client. Fencing sits in the placed and controlled column of Thrare Contracting's trade capabilities, beside painting and modular work, rather than in the self-performed column that holds concrete and flatwork, pavement striping, debris removal and hauling, property preservation and commercial pressure washing.
A fence firm clears a qualification file before assignment rather than after award. That file covers six items: license where the scope and the jurisdiction require one, current insurance certificates with limits appropriate to the scope and the site, evidence the firm can reach the site and carry the volume on the schedule, references on comparable prior work that get checked rather than collected, written agreement on what finished looks like, and corrective action rights in the trade firm agreement so a defect has a defined remedy.
Naming the model matters to a buyer, because the buyer is choosing who carries the risk. On a Thrare Contracting fencing project the trade firm holds the tool and Thrare Contracting holds the outcome. Which column a scope sits in is written into the proposal before signature.
Thrare Contracting places eight fencing scopes in Atlanta, and each one is specified by material, height, gauge or section, coating, footing depth and gate hardware before a trade firm is assigned.
Fencing on a commercial or public property in Atlanta does one of seven jobs, and the job decides the specification.
Thrare Contracting runs a fencing project in eight steps, and the client sees the same eight on every job.
Thrare Contracting prices a fencing scope with the included and excluded items written on the same page, because an exclusion found after mobilization is a change order and an exclusion found before signature is a decision.
Included in the base price:
Not included unless the scope document says so:
Thrare Contracting's one published public sector performance figure is $198,000 in recycled aggregate supplied to Fulton County Public Works. That figure covers a materials scope rather than a fencing scope, and Thrare Contracting publishes no fencing production numbers, crew counts or year totals, because none have been verified for publication.
Setting fence posts with an auger is mechanized excavation, and Georgia law requires notice to the Utilities Protection Center before that work starts. Section 25-9-6 of the Official Code of Georgia Annotated, part of the Georgia Utility Facility Protection Act, states that no person shall commence, perform, or engage in blasting or in excavating with mechanized excavating equipment on any tract or parcel of land in any county in this state unless and until the person planning the blasting or excavating has given 48 hours' notice by submitting a locate request to the UPC, beginning the next business day after such notice is provided, excluding hours during days other than business days.
Georgia 811, the Utilities Protection Center for the state, instructs excavators in its 2025 Excavator Manual to wait the required amount of time, which the manual states as at least 3 business days, and to read the effective date printed on the locate request. The same manual defines business days as Monday through Friday between 7:00 a.m. and 4:30 p.m. with the exception of major holidays.
Georgia 811 also publishes a tolerance zone of 18 inches on either side of the outer edge of a marked utility facility, inside which the excavator must exercise reasonable care through hand digging, pot holing or soft digging. A normal locate request lives 30 calendar days after its effective date, per the same manual.
The schedule consequence is direct, and a buyer in Atlanta plans around it: a fence line cannot be augered on the day the work is released. Thrare Contracting builds the locate wait into the schedule in the proposal rather than absorbing it as a delay later.
Georgia Department of Public Health Rule 511-3-5-.18(11) requires all outdoor swimming pools and spas to be enclosed by a barrier to prevent entry to the pool area when the pool is closed. The rule sets the top of the barrier at least forty eight inches above grade measured on the side of the barrier which faces away from the swimming pool, a maximum vertical clearance of four inches between a solid surface and the bottom of the barrier, and a maximum of two inches over non-solid surfaces for a barrier constructed after the chapter was adopted.
The rule also governs what the barrier is made of. Openings in the barrier shall not allow passage of a four inch diameter sphere. Where horizontal and vertical members are less than forty-five inches apart at the tops of the horizontal members, the horizontal members shall sit on the pool side of the fence and spacing between vertical members shall not exceed one and three-fourths inches. Maximum mesh size for chain link is one and three-fourths inches unless slats fastened at the top or the bottom reduce the openings to that dimension.
Access gates carry their own requirements under the same rule. Pedestrian access gates shall be self-closing and have a self-latching device, barrier gates in facilities constructed after the chapter was adopted shall open away from the pool, and a mechanism controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.
The rule reaches the pools a multifamily and institutional owner actually operates. Rule 511-3-5-.01 defines a public swimming pool to include municipal, school, hotel and motel pools, and pools and spas operated by or serving camps, churches, day care centers, institutions, parks, state agencies, condominiums, mobile home parks, recreational vehicle parks, associations and health clubs. A pool barrier scope in Atlanta gets specified against that rule before a trade firm is assigned.
Thrare Contracting confirms which authority has jurisdiction over the parcel before a fencing scope is priced, because a parcel inside the Atlanta city limits and a parcel in unincorporated Fulton County are permitted by different offices. Permit responsibility and who pays the fee are written into the scope document rather than assumed.
Four items decide whether a fence design survives review: height limits by zoning district and by yard or frontage, setbacks from property lines, easements and rights of way, sight distance at driveways and intersections, and any overlay or design district standard that applies to the parcel. Thrare Contracting resolves those four before the material is ordered, because a fence corrected after installation is paid for twice.
Thrare Contracting needs eight things to price a fencing scope, and a complete set turns a site walk into a number rather than a conversation.
Thrare Contracting holds DBE, MBE and SDB certification and is registered in SAM.gov under UEI Z4WKS4UE8NJ6 and CAGE code 9JAV8. Those credentials qualify Thrare Contracting for diversity participation requirements on publicly funded work and satisfy the federal registration requirement for a prime or subcontract award. Thrare Contracting does not hold HUBZone, 8(a) or SOC 2, and does not represent otherwise.
Thrare Contracting is the trading name of Rare Earth Ltd, at 8735 Dunwoody Pl, Ste R, Atlanta, GA 30350. Related pages cover government contracting services, commercial property programs, and the DBE and MBE certifications in more detail.
No. Thrare Contracting does not sell fencing to homeowners. The only residential service Thrare Contracting offers is pressure washing. Every fencing scope Thrare Contracting takes in Atlanta is written for a commercial, government, institutional or multifamily property.
No. Thrare Contracting scopes the fencing, places it with qualified fence contractors, inspects against written acceptance criteria and owns the outcome to the client. Fencing sits in the placed and controlled column of Thrare Contracting's trade capabilities, beside painting and modular work.
Section 25-9-6 of the Official Code of Georgia Annotated requires 48 hours' notice by submitting a locate request to the Utilities Protection Center, beginning the next business day after the notice is provided and excluding hours during days other than business days. Georgia 811's 2025 Excavator Manual tells excavators to wait at least 3 business days and to read the effective date printed on the locate request.
Georgia Department of Public Health Rule 511-3-5-.18(11) sets the top of the barrier at least forty eight inches above grade measured on the side of the barrier which faces away from the swimming pool. Openings in the barrier shall not allow passage of a four inch diameter sphere, and pedestrian access gates shall be self-closing and have a self-latching device.
Permit fees paid to the jurisdiction, rock excavation beyond the depth the price assumes, relocation of a utility facility marked inside the tolerance zone, a boundary survey where the property line is disputed, electrical service to a powered gate operator, and integration to an access control head end sit outside the base fencing price. Each exclusion is listed in the scope document before signature.
Thrare Contracting holds DBE, MBE and SDB certification and is registered in SAM.gov under UEI Z4WKS4UE8NJ6 and CAGE code 9JAV8. Thrare Contracting does not hold HUBZone, 8(a) or SOC 2.
Tell us the property, the fence type, the linear footage and the acceptance date. Thrare Contracting walks the line, writes the scope with the exclusions on the same page, and places it with a qualified fence contractor.